工業(yè)冷凍機(jī)是一款可以提供工藝低溫冷凍水的制冷設(shè)備,溫度不僅可控制在0~35℃,更可以控制在零下40℃,從而達(dá)到工業(yè)制冷的目的。下面機(jī)械就為您介紹如何正 確使用工業(yè)冷凍機(jī)。
1、來(lái)操作這臺(tái)工業(yè)冷凍機(jī)的操作人員,一定要有工作經(jīng)驗(yàn),并經(jīng)過(guò)相關(guān)培訓(xùn),掌握操作技能,能夠遵守安全操作規(guī)程來(lái)進(jìn)行工作。
2、在操作冷凍機(jī)之前,要先檢查冷卻水閥是否打開(kāi),冷凍機(jī)的水箱是否有加滿(mǎn)水,冷卻水壓是否正常,切忌在缺水時(shí)進(jìn)行操作。
3、水冷式冷凍機(jī)的開(kāi)啟順序是:先開(kāi)冷卻水泵,再開(kāi)啟壓縮機(jī);而關(guān)機(jī)順序則是先關(guān)閉壓縮機(jī),然后關(guān)閉冷卻水泵。
4、工業(yè)冷凍機(jī)的冷凍水溫度不可設(shè)置太低,否則會(huì)降低機(jī)組的制冷效率,并有可能導(dǎo)致機(jī)組出現(xiàn)低溫保護(hù)動(dòng)作而停機(jī)。您將溫度設(shè)定在工廠需求溫度稍低即可,必要時(shí)可以一邊操作一邊調(diào)試,根據(jù)實(shí)際需要來(lái)調(diào)設(shè)水溫。
5、當(dāng)工業(yè)冷凍機(jī)出現(xiàn)故障報(bào)警導(dǎo)致停機(jī)后,一定要先將機(jī)組停機(jī)(按停機(jī)按鈕),然后檢查故障原因,在故障沒(méi)有排除前不得強(qiáng)行開(kāi)機(jī)運(yùn)行。故障問(wèn)題嚴(yán)重時(shí),請(qǐng)記得聯(lián)系工業(yè)冷凍機(jī)廠家來(lái)進(jìn)行維修處理。
6、在沒(méi)有緊急的情況下,不可通過(guò)切斷主機(jī)電源來(lái)關(guān)閉機(jī)組。如果在運(yùn)行時(shí)工業(yè)冷凍機(jī)發(fā)生異常情況,應(yīng)立即關(guān)閉電源并通知維修人員處理。
7、如果在冬季不需要使用工業(yè)冷凍機(jī),機(jī)組要長(zhǎng)期停止運(yùn)行,請(qǐng)先關(guān)閉機(jī)組,再關(guān)閉電源。記得一定要將系統(tǒng)內(nèi)部的水排放干凈,并用布罩將冷凍機(jī)遮蓋起來(lái)。
For foreigner
The industrial refrigerator is a refrigeration equipment which can provide the process of low temperature chilled water. The temperature can be controlled not only at 0~35 degrees, but also at 40 degrees below zero, so as to achieve the purpose of industrial refrigeration. Following the Teng machinery, for you to introduce how to correctly use industrial refrigerators.
1, to operate the industrial refrigerator operators, must have work experience, and through the relevant training, master the operation skills, be able to comply with the safety operation regulations to work.
2, before the operation of the refrigerator, check whether the cooling water valve is opened, the refrigerator water tank is filled with water, cooling water pressure is normal, and must not operate in water shortage.
3. The opening sequence of water-cooled chiller is: first open the cooling water pump, then open the compressor; and the order of shutdown is to turn off the compressor first, then turn off the cooling water pump.
4, industrial refrigeration chiller water temperature can not be set too low, otherwise it will reduce the unit cooling efficiency, and may cause the unit to appear low temperature protection action and stop. You set the temperature in the factory demand temperature is slightly lower, if necessary, you can operate while debugging, according to actual needs to adjust the water temperature.
5, when the industrial refrigerator malfunction alarm, resulting in downtime, we must first stop the machine (press the stop button), and then check the cause of the failure, the failure is not ruled out, not forced to start running. When the trouble is serious, please remember to contact the industrial refrigerator manufacturer for maintenance.
6, in the absence of emergency circumstances, not by cutting off the main power supply to shut down the unit. If there is an abnormal situation in the industrial chiller at the time of operation, the power shall be switched off immediately and notify the maintenance personnel to deal with it.
7, if you do not need to use industrial refrigerators in winter, the unit will stop running for a long time, please turn off the power unit first, then turn off the power supply. Remember to clean the water inside the system and cover the freezer with a cloth cover.